Precast Floor Slab Stitch Reinforcement System

S&P C-Laminate LM combined with S&P Resin 220HP epoxy adhesive is the ideal solution for suspect precast floor slabs. The system has been fully tested and can be installed with minimal disruption.
Following the collapse of the car park in Eindhoven, we brought together our international knowledge and experience and set out to find a suitable solution. As a manufacturer and supplier of carbon-fibre-based materials, we are close to the market and are an independent partner for all structural engineers.
Our S&P C-Laminate has been used successfully for 25 years in strengthening concrete structures in the broadest sense of the term. Applications range from openings, voids and spans to reducing existing reinforcement (corrosion) in civil engineering structures. Our carbon-fibre reinforcement is also used in repairs to cantilevered balconies and walkways, and to strengthen masonry in earthquake-prone areas.
The S&P Precast Floor Slab Stitch Reinforcement System has been investigated and tested on comparable precast floor slab elements at TU Eindhoven. Working with renowned partners, we developed a repair system, including a calculation model. In addition to proven structural safety, the strengthening work has little impact on the surrounding area and keeps disruption to a minimum.
The test specimens were designed and dimensioned to be identical to the slabs involved in the incident at the car park in Eindhoven.
The cause of the slab collapse in the car park in Eindhoven was established before the investigation began.
The investigation at TU Eindhoven examined:
• Whether bonding an external carbon-fibre laminate could be used as a strengthening measure.
• Whether the loads ultimately achieved would match those predicted by theoretical calculations and computer simulations in DIANA.”
Various tests were carried out using different quantities of carbon-fibre laminates. In addition, slabs were preloaded with an initial debonding between the precast shell and the topping to simulate existing delamination. The conclusion of all these investigations is that the strengthening measure performs excellently, and the ultimate failure loads measured during the tests fully match the computer models.
S&P Precast Floor Slab Stitch Reinforcement System:
- S&P provides full technical support
- System extensively tested
- Various references available
- No risk of drilling through existing reinforcement, concrete core activation systems or pipes
- Can be used in buildings while they remain occupied
- Dust-free system
- Very little or no noise disturbance
- Lightweight
- Easy to install, with full installer training
Fire protection
In most cases, fire protection for the carbon-fibre reinforcement bonded with adhesive is not necessary. Where fire protection is required, S&P offers a standard solution providing 30, 60, 90 or 120 min of fire resistance.